MULTICAL®
602
22
Kamstrup
A/S
∙
Technical
Description
∙
5512
‐
931_N1_GB_11.2016
Dat
e
stam
p
He
at
met
e
r
D
D
D
=
210
Cooling meter
D
D
D
=
510
Heat/cooling
D
D
D
=
610
He
at
volu
me
D
D
D
=
710
Cold volume
D
D
D
=
810
Energy meter
D
D
D
=
910
15.0 VA
(Input
A)
11 9 10 5 5 14
15.1
Meter no. VA
11A 9A 10A 5A 5A 14A
15.2 Yearly
data
11B 9B 10B 5B 5B 14B
15.3 Monthly
data
11C 9C 10C 5C 5C 14C
15.4
L/Imp for VA
(N
o
65)
11D 9D 10D 5D 5D 14D
16.0
VB (Input B)
12 10 11 6 6 15
16.1
Meter no. VB
12A 10A 11A 6A 6A 15A
16.2 Yearly
data
12B 10B 11B 6B 6B 15B
16.3 Monthly
data
12C 10C 11C 6C 6C 15C
16.4
L/Imp for VB
(N
o
67)
12D 10D 11D 6D 6D 15D
17.0 TA2
13
12
17.1 TL2
13A
18.0 TA3
14
13
18.1 TL3
14A
19.0 Info
code
15 11 14 7 7 16
19.1
Info event counter
15A 11A 14A 7A 7A 16A
19.2
Info logger (last 36 events)
15B 11B 14B 7B 7B 16B
20.0
Customer number
(N
o
1+2)
16 12 15 8 8 17
20.1 Date
16A 12A 15A 8A 8A 17A
20.2 Time
16B 12B 15B 8B 8B 17B
20.3 Target
date
16C 12C 15C 8C 8C 17C
20.4
Serial no.
(N
o
3)
16D 12D 15D 8D 8D 17D
20.5 Prog.
(A-B-CCC-CCC)
(N
o
4)
16E 12E 15E 8E 8E 17E
20.6
Config 1 (DDD-EE)
(N
o
5)
16F 12F 15F 8F 8F 17F
20.7
Config 2 (FF-GG-M-N-T)
(N
o
6)
16G 12G 15G 8G 8G 17G
20.8
Software edition
(N
o
10)
16H 12H 15H 8H 8H 17H
20.9
Software check-sum
(N
o
11)
16I 12I 15I 8I 8I 17I
20.10 Segment
test
16J 12J 15J 8J 8J 17J
20.11
Top module type
(N
o
20)
16K 12K 15K 8K 8K 17K
20.12
Top module primary adr.
(N
o
21)
16L 12L 15L 8L 8L 17L
20.13
Top module second. adr.
(N
o
22)
16M 12M 15M 8M 8M 17M
20.14
Base module type
(N
o
30)
16N 12N 15N 8N 8N 17N
20.15
Base module primary adr.
(N
o
31)
16O 12O 15O 8O 8O 17O
20.16
Base module second. adr.
(N
o
32)
16P 12P 15P 8P 8P 17P
Number of yearly data shown in the display (1…15)
2 2 2 2 2 2
Number of monthly data shown in the display (1…36)
12 12 12 12 12 12
DDD=210 is the ”standard code” for heat meters with meter type 602xxxxxxx2xx. Please contact Kamstrup for other
combinations. Max. number of readings of a DDD code is 110. Of these, reading of data logger counts for 4 readings.
Top module no. and base module no. to be left out of account.
Note: Data reading can retrieve up to 36 monthly data and up to 15 yearly data. Number of yearly and monthly data
to be shown in the display is determined by the DDD code in each case.