MULTICAL®
602
48
Kamstrup
A/S
∙
Technical
Description
∙
5512
‐
931_N1_GB_11.2016
6.11
Info codes
MULTICAL
602 constantly surveys a number of important functions. Where serious errors have occured in the
measuring system or in the installation, a flashing "INFO" will appear in the display while the error exists. The “INFO”
panel will flash for as long as the error exists no matter which reading is selected. The " INFO " panel will
automatically turn off, when the source of error has been corrected.
6.11.1
Examples of info codes on the display
Ex. 1
Flashing ” INFO”
If the info code exceeds 0 a flashing " INFO " will
appear in the information panel.
Ex. 2
Current info code
When the upper (primary) push button is activated
several times the current info code can be shown on
the display.
Ex. 3
Info event counter
- indicates how many times the info code has been
changed.
Ex. 4
Info logger
By pressing the lower push button once more the
data logger for the info code is displayed.
First, the date of the first change is displayed …
…then the info code appearing on that particular date
is displayed. In this case there has been a "bursting
alarm" on 4
th
January 2011.
The data logger stores the last 50 changes, of which
the last 36 changes are shown in the display. All 50
changes can be read by means of LogView/MT Pro.
Time, E1 (heat energy) and E3 (Cooling energy – if available) will be logged when the info code is changed.
Naturally, the info code will still be logged during changed info codes. To read out Time and E1 together with the
info code it is necessary to use LogView.
In addition, the info code is stored in the hourly logger, the daily logger, the monthly logger and the yearly logger
for diagnostic purposes.