6.11.4
Info event counter
Info event counter
Counting takes place every time the info code is
changed.
The info event counter will be 0 on receipt, as
"transport mode" prevents counting during transport
Info code
”INFO” on display
Registration in the info,
daily, monthly or yearly
logger
Counting of info events
1
No Yes At each ”Power-On-Reset”
4, 8, 32
Yes Yes
When info 4, 8, 32 are set or removed.
Max. 1 per measurement of temperature
64, 256
Yes Yes
When info is set and when info is deleted.
Max. 1 time/day
512
Yes Yes
When info is set and when info is deleted.
Max. 1 time/120 s
16, 1024, 2048, 4096,
8192, 16384, 32768
Yes Yes
When info is set and when info is deleted.
Max. 1 time/day
6.11.5
Error hour counter
An error hour counter is added. This will sum up the approx. number of hours with info code
zero.