Use the
no
version to remove the protect interface from the APS group.
■
See aps protect.
aps revert
■
Use to revert to the original working interface when it recovers.
■
Specify the number of minutes in the range 5–7, after which the router will
switch to the working interface.
■
You can issue this command only for the protect interface, not for the working
interface.
■
Example
host1(config-controll)#
aps revert 7
■
Use the
no
version to restore the default setting, in which the router does not
revert to the working interface when it recovers.
■
See aps revert.
aps unidirectional
■
Use to specify that the router should switch to the protect interface using the
unidirectional mode switching mechanism.
■
You can issue this command only for the protect interface, not for the working
interface.
■
Example
host1(config-controller)#
aps unidirectional
■
Use the
no
version to restore the default setting, bidirectional mode.
■
See aps unidirectional.
Configuring SONET/SDH Alarms
To configure the bit error rates that determine signal degradation and signal failure
on the working interface:
1.
Select the protect interface.
host1(config)#
controller sonet 4/1
2.
Specify the bit error rate at which the router should generate an alarm indicating
signal degradation.
host1(config-controller)#
threshold sd-ber 6
3.
Specify the bit error rate at which the router should generate an alarm indicating
signal failure and switch from the working interface to the protect interface.
host1(config-controller)#
threshold sf-ber 5
Configuration Tasks
■
93
Chapter 3: Configuring Unchannelized OCx/STMx Interfaces
Содержание JUNOSE 10.0.X PHYSICAL LAYER
Страница 6: ...vi...
Страница 8: ...viii JUNOSe 10 0 x Physical Layer Configuration Guide...
Страница 16: ...xvi List of Figures JUNOSe 10 0 x Physical Layer Configuration Guide...
Страница 18: ...xviii List of Tables JUNOSe 10 0 x Physical Layer Configuration Guide...
Страница 28: ...2 Chapters JUNOSe 10 0 x Physical Layer Configuration Guide...
Страница 98: ...72 Monitoring Interfaces JUNOSe 10 0 x Physical Layer Configuration Guide...
Страница 200: ...174 Monitoring Interfaces JUNOSe 10 0 x Physical Layer Configuration Guide...
Страница 253: ...Part 2 Index Index on page 229 Index 227...
Страница 254: ...228 Index JUNOSe 10 0 x Physical Layer Configuration Guide...
Страница 262: ...236 Index JUNOSe 10 0 x Physical Layer Configuration Guide...