02.15 EN
50
LED display (43)
Compensation charge
The compensation charge starts automatically when charging is complete.
Partial charging
The charger is designed to automatically adapt to partially charged batteries. This
keeps battery wear to a minimum.
Green LED (charge status)
Lit
Charging complete, battery full.
(Charge interval, float or
compensation charge).
Slow flash
Charging.
Rapid flash
Display at beginning of charge or
after setting a new characteristic
curve. Number of flash pulses
corresponds to the characteristic
curve set.
Red LED (fault)
Lit
Charging characteristics or battery parameters
invalid
Slow flash
1xflash with noticeable interval: Overvoltage
detected before charging starts
2xflash with noticeable interval: Max. charge time
exceeded
3xflash with noticeable interval: Max. charge
capacity exceeded
4xflash with noticeable interval: Control deviation
lmax
5xflash with noticeable interval: Overvoltage cutout
6xflash with noticeable interval: Low voltage cutout
7xflash with noticeable interval: Battery is faulty,
battery error
8xflash with noticeable interval: Fan error
9xflash with noticeable interval: Battery
disconnected from charger during charging.
10xflash with noticeable interval: Equipment
overtemperature
43
Содержание ERE 120
Страница 1: ...07 12 02 15 51222183 ERE 120 Operating instructions G ERE C20 ERE 120...
Страница 3: ...02 15 EN 4...
Страница 9: ...02 15 EN 10...
Страница 11: ...0506 GB 2...
Страница 35: ...02 15 EN 34 The truck can now be lifted by crane...
Страница 39: ...02 15 EN 38...
Страница 55: ...02 15 EN 54...
Страница 58: ...57 02 15 EN 2 Displays and Controls V R 49 50 5 51 50 49 11 52 53 54 7 9 8 10 6 5 48 48...
Страница 64: ...63 02 15 EN 54 56 51 6 9 52 8...
Страница 76: ...75 02 15 EN R V R V 0 B B B F 5 48 8 10 6 5 48 11...
Страница 88: ...87 02 15 EN...
Страница 93: ...02 15 EN 92 WARNING Only return the truck to service when you have identified and rectified the fault 57...
Страница 157: ......