Green Heating Technology
8
Two digit display under the symbol
Normally, it displays the
CH flow
temperature, i.e the temperature of the liquid on boiler's
outlet that is sent to the CH system.
During the CH temperature setting (by rotating the knob
), it shows the
temperature value changing
; in case of
alarm it displays "E"
; during the
setting (re
-
served to the Technician)
it displays the chosen
parameter ID number
(see "PCB param-
eters settings (technician menu)" on page 27).
Three digit display under the symbol
Normally, it displays the temperature of the hot water in the storage. When the boiler is in
stand-by mode, it displays
.
During the DHW temperature setting (by rotating the knob
), it shows the
temperature
value changing
; in case of
alarm
it displays the
ID number
of the alarm (see "Alarms -
boiler block" on page 32); during the
setting (reserved to the Technician)
it displays
the
value
of the chosen
parameter
�
RESET
It appears when the boiler is locked or anyway is present an error that the user could man-
age. See "Alarms - boiler block" on page 32 to identify the problem and the relevant
actions to be carried out.
SERVICE
It appears when the boiler has detected an error (mainly a fault) that has to be managed
by the Technician. The User can anyway see "Alarms - boiler block" on page 32 to get
information about and the eventual actions to be carried out.
It informs that the outdoor probe (accessories) is installed.
Note:
In
this case the CH system temperature is automatically set and so the
use of the
knob
is different from the standard way: for deeper detail
s rely on kit
instruction
and see "Outdoor Sensor Kit" on page 46.
Commands on the lower side
1
System pressure gauge
2
GAS cock
Commands outside the boiler
Externally the boiler, suitably positioned in the building
(generally by the installer or by the electrician), some
devices that the user should access to, are present. The
presence and the characteristics of these devices are pre-
scribed by the regulation in force.
Two-pole switch:
it is located usually close to the boiler and it's for electrically insulating the boiler
itself from the domestic mains power supply network. It is useful to disconnect the boiler from the
electrical supply, e.g. during inactivity periods (see "Safety shut off" on page 11) or in some cases
of alarm (see "Alarms - boiler block" on page 32).
Room thermostat:
it commands electrically the boiler to activate or deactivate the heating system, in
order to keep the room temperature (detected by a sensor) within a value set by the user, Regula-