Param
-
eter
Adj. range
(fact. set.)
and values
Description
06
0…15
(3)
Value in minutes. Delay of boiler re-ignition after set Central Heating tem-
perature has been reached.
(This parameter works only if par. 05 = 0)
07
0…3
(0)
Auxiliary maintenance functions
0
Disabled
- normal operation of the boiler
(Remember to set this value to 0 at the end of work)
1
function Bleeding on heating side
- boiler puts 3-way valve on the heating
side and pump is continuously powered
2
function Bleeding on DHW side
- boiler puts 3-way valve on the DHW side
and pump is continuously powered
3
function Bleeding both Heating and DHW side
- boiler cyclically moves the
3-way valve on heating and DHW sides, and pump is continuously powered
Remark:
Auxiliary maintenance functions stay active for about 15 minutes, then the parameter is automatically set
back to 0. To stop the function manually, set the value to 0 or quit the Technical Menu.
08
0…2
(1)
Primary circuit working temperatures during DHW demand
0
dynamics
- Do not use in this type of boiler
(only for models with flow meter instead of flow switch)
1
fixed
- burner OFF at 75°C and burner ON at 65°C
2
linked
to DHW SET: Burner OFF when DHW tempe 3 ° C and burner
ON when DHW tempe 2 ° C
12
0…2
(0)
Chimney-sweeper” function: burner ignition, not modulated, to allow the
combustion check. For deeper details see paragraph "Combustion test" on
page 29.
0
burner off - normal boiler work
(rimember to reset this parameter to value 0)
1
burner ignition at
maximum output
2
burner ignition at
minimum output
Remark:
During this phase, the delay between burner ignitions is zero, so if flow temperature is close to maximum,
frequent re-ignitions of the burner could take place.
23
0; 30…60
(0)
DHW temperature (storage preparation)
0
By user controls
- The adjustment of the DHW temperature is allowed to the
User, by means of the knob
.
30…60
User controls disabled
- If there is some reason to disable the knob
, and
disallow the user to set the DHW temperature, choose a value different from
0 that will correspond to the set temperature.
25
0…10
(3)
Temperature hysteresis (°C) for storage preparation. It determinates how
many degrees has the DHW temperature to decrease compared to the set
one, to generate a preparation request.
26
5…15
(8)
Differential (°C) for max flow temperature.