For the general electrical supply of the appliance the bipolar switch should be used. The use of adaptors,
multiple taps and extensions is not allowed.
If the supply cable must be replaced, use one of the following cable types: H05VVF or H05-VVH2-F.
It is
mandatory the earth connection in accordance with the rules actually in force.
To replace the cable,
open the control panel cover, unlock its fastening device and disconnect it from the terminals.
Install
the new cable proceeding in the reverse way. When connecting the cable to the boiler, it’s mandatory:
• to leave the Earth wire about 2 cm longer than the other (Live and Neutral) wires;
• to lock the cable upstream the terminals by means of the suitable fastening device.
Electrical safety of the appliance is only achieved when it is well connected to an efficient earth-
ing system, executed as indicated by the safety rules actually in force.
A qualified technician must check that the electrical system is in line with the maximum power allowed
by the boiler, indicated on the data plate, with particular attention to the cables section.
ITALTHERM S.r.l. declines any responsibility for damages to persons, animals or things caused by
the faulty or missing connection of the boiler earthing and by failure to comply with the rules.
Electrical connection between the boiler and the storage unit
NEVER
connect the wirings described below, to the power supply or to live wires.
As shown in "Electrical diagram" on page 44, the boiler has two different inputs for the electrical con-
nections to the storage unit:
SP: input
for the
Storage temperature Probe
: the boiler reads the storage temperature and, if necessary,
switches to storage heating mode to keep its temperature around the value set by means of the user
control
. Even if the storage unit is supplied by a third manufacturer, it's necessary to
use the
original temperature probe kit
(NTC R=10 kOhm at 25°C, ß=3435). Only
if the SP input is used
, it's
necessary to
remove the factory-installed resistor
, that
otherwise must be left installed.
ST: input
for
Storage Thermostat
or
solar DHW heating request
: when the contact is closed, the boiler
work is forced in DHW storage heating, until it opens (or up to the reaching of the max boiler tem-
perature). To be used in case the storage has a thermostatic temperature control (even manually
adjustable) or in connection with a solar system, to allow it to require the heating of the storage
when the solar heat contribution is insufficient.
The cabling between the Storage temperature Probe SP and the boiler must pass in a sheath
separate from the ones containing supply cables.
In every case, the maximum length for a 2 x 0.5mm² cable is 30m.
Remark:
if both inputs are used, the heating of the storage is commanded by any one of them.