13
“Ambient Anti-Frost” Function
Note:
if you want to use the “Ambient Anti-Frost” function that is often available in common room
thermostats or chronothermostats, it is necessary
NOT to leave the boiler in
mode
but in
a mode that allows the heating, e.g. Heating Only mode
(that saves from useless heating of
the DHW storage, although keeping its anti-freeze function active)
,
or in Winter
+
mode.
The “Ambient Anti-Frost” function does not protect the sanitary circuit outside the boiler and,
especially, in areas where the heating system doesn’t reach. For this reason, we recommend
that you empty the cold and hot sanitary water, including the DHW storage, from the parts of
the system that are at risk of freezing.
Installation
Law and regulation prescriptions for the installer
Always comply with national and/or local regulation about BOILER INSTALLATION.
Always comply with national and/or local regulation about WORK SAFETY of Personnel in
charge of installation.
Characteristics of the room:
as this boiler has an heat output lower than 35 kW (about 30000 Kcal/h),
it is not required to install the appliance in a dedicated room, provided that the room complies with
the regulation in force and that all installation rules assuring a safe and regular gas boiler operation,
are strictly respected�
Permanent ventilation of the installation room is mandatory and extremely important
when
a boiler with air draught from the installation room (B… appliance type) is installed. Ventilation
must be made and sized in compliance with Laws and Rules in force.
Presence of other appliances:
the presence of other appliances (especially if they interfere with the
boiler draught) can be forbidden by the regulation in force or can require modifications (e.g. the
enlargement of the ventilation opening or the making of new ones).
Instructing the user:
at the end of the installation, the installer must:
• explain the operation of the boiler and its safety devices to the user;
• give this user this booklet and the documentation within his/her competence, duly filled in where
required.