Green Heating Technology
39
TECHNICAL DATA
(cont'd)
U.M.
City Class 20 FR
City Class 25 FR
Gas type
G20
G30/G31
G20
G30/G31
Hot water
Temperature selection range
(min÷max)
°C
30÷60
30÷60
Electrical data
Voltage / frequency
(nominal voltage)
V / Hz
220÷240 / 50
(230V)
220÷240 / 50
(230V)
Power consumption
W
103
103
Level of protection
IP X5D
IP X5D
Dimensions
Width - Height - Depth
mm
see "Dimensions and connections" on page 14
Weight: net / gross
kg
27.5 / 29.7
30.2 / 32.6
Connections
Hydraulic and gas connections
see "Dimensions and connections" on page 14
Flue:
types, lengths and diameters
see "Flue systems" on page 22
Gas supply pressure
Nominal pressure
mbar
20
37
20
37
Inlet pressure (min÷max)
mbar
17 ÷ 25
35÷40
17 ÷ 25
35÷40
Injectors number
9
11
Injectors diameter
mm/100
130
78
130
78
Gas pressure to injectors at Qn (MAX)
mbar
12.4
27.8 / 35.7
13.0
27.5 / 35.6
Gas pressure to injectors at Qr (MIN)
mbar
2.4
6.5 / 6.5
1.9
4.9 / 4.9
Gas consumption
at Qn
m³/h
2.22
2.72
kg/h
1.61 / 1.59
2.01 / 1.98
at Qr
m³/h
1.00
1.06
kg/h
0.79 / 0.78
0.80 / 0.79
Note:
data have been measured with minimum length coaxial flue (see "Flue systems" on page 22).
Содержание CITY GLASS 20 FR