![Isokern Magnum 86072-60 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/isokern/magnum-86072-60/magnum-86072-60_installation-operation-and-owners-manual_2093413006.webp)
Safety Instructions
1.
Before starting the Magnum 86072 Series fireplace and
DM chimney installation, read these installation instructions
carefully to be sure you understand them completely. Failure
to follow them could cause fireplace malfunction resulting in
serious injury or property damage.
2.
Always check local building codes governing fireplaces and
fireplace installations. The Magnum 86072 Series fireplace and
DM chimney installation must comply with all local, regional,
state and national codes and regulations.
3.
Magnum 86072 Series fireplace and DM chimney systems
are intended for use in any application where a traditional
masonry type fireplace would apply. The chimney system must
always vent vertically to the outside of the building.
4.
Creosote and soot formation and the need for removal: When
wood is burned slowly, it produces tar and other organic vapors
which combine with expelled moisture to form creosote. The
creosote vapors condense in the relatively cool chimney flue of
a slow burning fire. As a result, creosote residue accumulates
on the flue lining. When ignited this creosote makes an
extremely hot fire.
Because of creosote and soot buildup it is necessary
to inspect and clean the fireplace and chimney prior to use
and periodically during the heating season. Cleaning of the
fireplace and the chimney system should be done annually at
a minimum. In colder climates, chimney cleaning may need to
be done periodically throughout the heating season.
5.
Before servicing, allow the fireplace to cool. Always shut
off any electricity or gas to the fireplace while working on it.
6.
Use only solid fuel or natural or LP gas log sets in this
unit. Do not use artificial wax based logs, chemical chimney
cleaners or flame colorants in this fireplace.
7.
Never use gasoline, kerosene, gasoline-type lantern fuel,
charcoal lighter fluid, or similar liquids to start or “freshen up”
a fire in this fireplace. Keep all flammable liquids at a safe
distance from the fireplace.
8.
Always keep the flue damper open when heat is present in
the fireplace.
9.
Do not use a fireplace insert or any other product not
specified for use with the Magnum 86072 Series fireplace and
DM chimney systems unless written authorization is given by
Earthcore. Failure to heed this warning may cause a fire hazard
and will void the warranty.
10.
This fireplace is not intended to heat an entire home or
to be used as a primary heat source. It is designed to ensure
homeowner comfort by providing supplemental heat to the
room.
11.
Always ensure that an adequate supply of replacement
combustion air from the outside of the house is accessible to
the fire to support normal combustion. Fireplaces consume
large volumes of air during the normal firing process.
In the event the home is tightly sealed and has modern
energy efficient features, the optional combustion air supply
kits may not provide all the air required to support combustion
and the proper flow of combustion gases up the chimney.
The manufacturer is not responsible for any smoking
or related problems that may result from the lack of adequate
air supply flowing into the house. It is the responsibility of the
builder/contractor to ensure that adequate air supply has been
provided for the fireplace.
12.
“Smoke free” operation is not warranted nor is the
manufacturer responsible for inadequate system draft caused
by mechanical systems, general construction conditions,
inadequate chimney heights, adverse wind conditions or
any unusual environmental conditions or factors beyond the
manufacturer’s control.
Caution:
When used with the Magnum 86072 Series fireplace
system, all gas log sets must be operated with the damper
clamped in the fully open position. This includes unlisted
“vent free” log sets. Only listed “vent free” log sets may be
operated with the damper in the closed position.
13.
When in doubt about a component’s usability - has visible
or suspected physical damage - consult your Isokern distributor
or authorized Isokern representative for advice.
14.
Modification to Magnum 86072components not mentioned
in this manual may void claims, listings and approvals and
could result in an unsafe and potentially dangerous installation.
Alterations to the Magnum 86072 firebox are allowed
with prior written approval and instructions from Earthcore
Industries, LLC. The installer indemnifies the manufacturer of
all claims and under no circumstances will manufacturer be
liable for consequential, incidental, indirect, punitive or other
damages of any kind or nature, whether foreseeable or not,
based on any claim by any party as to the modifications of the
Isokern fireplaces.
15.
Keep all insulation, vapor barriers, “house wrap”
paper and other insulating type membranes and products,
including fiberglass, cellulose and other insulation,
(anything that carries an “R” rating) a minimum of three
inches (3”) away from all firebox and chimney surfaces.
Exception:
If insulation is used in walls surrounding the fireplace,
insulation may be installed behind sheathing of gypsom board,
plywood, particle board or other material on the side facing
the Isokern. The facing material cannot be within 1 1/2” to the
fireplace sidewalls.
WARNING:
Do not pack required air spaces with insulation
or other materials.
16.
Never leave children unattended when there is a fire
burning in the fireplace.
17.
Burning some fuels (such as charcoal) can be hazardous due
to the possibility of producing carbon monoxide, a colorless,
odorless gas. Early signs of carbon monoxide poisoning
resemble flu symptoms, including headaches, dizziness or
nausea. Over exposure to carbon monoxide can lead to illness
and death. It is strongly recommended to install smoke and
carbon monoxide alarm / detector devices wherever fireplaces
are in use.
6
Содержание Magnum 86072-60
Страница 2: ......
Страница 40: ...40 DM Chimney System Lateral Support cont FIGURE 81 FIGURE 82 ...
Страница 55: ...55 Notes ...