Assembly Instructions - Access Modification
Through-Wall Accesses:
1. Combustion Air Inlet: Combustion air inlet kits though not required
by Earthcore with other ventilating appliances installed.
Check local codes for combustion air inlet requirements.
The following is a general representation of a generic
combustion air kit and not a requirement of Earthcore Industries,
LLC. Local building codes prevail and should be checked before
installation.
Generic fireplace combustion air kits typically consist of a
sliding stainless steel access door affixed to a three inch (3”) or four
inch (4”) diameter stainless steel sleeve approximately twelve inches
(12”) long. An exterior vent with dress plate, weather hood and rodent
prevention screen of a maximum one-quarter inch (1/4”) wire mesh
completes the kit. (Figure 5)
The access door is fitted into the finished fire brick lining at the
interior sidewall of the Magnum 86072 firebox. The twelve inch (12”)
long sleeve can be introduced into the firebox side wall by core drilling
an appropriately sized hole at the selected firebox location. Keep the
top of the access hole no more than six inches (6”) above the finished
firebrick floor. The hole size should allow for a one-quarter inch (1/4”)
mortar joint around the air access sleeve for heat expansion.
The sleeve passes through the firebox wall and must be
connected to metal pipe (by other) - either flexible or rigid - that leads
to the source for outside combustion air, as directly as possible from the
Magnum 86072 Series fireplace (Few to no bends) with a maximum
length of sixty feet (60’).
WARNING:
Do not use combustible duct material. Avoid installing
a combustion air inlet where the opening could be blocked by snow,
bushes or other obstacles. Air inlet must terminate a minimum of three
feet below the chimney cap level. Air inlet ducts shall not terminate in
attic spaces.
2. Gas Line Feed: For a fireplace having the provision for installation of
a gas pipe, the provision is intended only for connection to a decorative
gas appliance.
CAUTION:
When using the decorative appliance, the fireplace damper
must be set in the fully open position. Gas line for gas log sets used in
the Isokern firebox can be routed through the side wall, by drilling an
appropriately sized hole using a masonry drill bit (Figure 7).
3. Electrical Line Feed can be routed through the Magnum 86072 firebox
side walls by drilling an appropriately sized hole using a masonry drill
bit (Figure 6). Be sure to follow the gas log Appliance Manufacturer’s
explicit electrical line connection instructions for vented masonry
fireplace installations.
Gas line and electric line must be fed through separate access holes.
CAUTION:
All access holes must be grouted with mortar – after line
or conduit feed - to seal any gaps or cracks around line feed conduits
(Figure 7).
FIGURE 5
AROUND CONDUIT WITH
NOTE: FILL ANY GAPS
MORTAR.
NON-COMBUSTIBLE).
TYPICAL PLACEMENT OF
(SEE DETAIL BELOW).
SUPPLY AIR VENTILATION
(IF REQUIRED BY CODE).
GAS OR ELECTRIC CONDUIT
FIRE BRICK SIDE
CONDUIT
GAS OR ELECTRIC
EXTERIOR
EXTERIOR AIR VENT
WITH DRESS PLATE.
WALL
FLEX DUCT TO FIREPLACE
FIREBOX, (ALL PARTS
FIGURE 6
FIGURE 7