![Isokern Magnum 86072-60 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/isokern/magnum-86072-60/magnum-86072-60_installation-operation-and-owners-manual_2093413005.webp)
Intended Use Statement
WARNING:
This fireplace has not been tested for use with
doors. To reduce the risk of fire or injury, do not install doors.
Operable doors are acceptable and if doors are required by the
local authority having jurisdiction, then doors must be kept
in the fully open position when the fireplace is in operation.
Isokern does not limit the use of fireplace screens.
Note
: Do not scale drawings. Illustrations in this manual are not
to scale and are intended to show “typical” installations.
Nominal dimensions are given for design and framing
reference only, since actual installations may vary due to
job specific design preferences. Always maintain the stated
minimum clearances to combustible materials. Do not violate
any specific installation requirements.
The Magnum 86072 Series fireplace and DM chimney
system is tested and listed by Warnock Hersey (Intertek Testing
Service) - Report No.
3082504-T1
- to UL 127, and UL
103HT.
Magnum 86072 Series fireplace systems are also
designed for installation in accordance with the National Fire
Protection Association Standard for chimneys, fireplaces, vents
and Solid Fuel-Burning Appliances (NFPA 211).
5
Intended Product Use Statement:
The Magnum 86072 Series fireplace and DM chimney
systems are intended to burn solid wood fuel, propane or natural
gas.
Note:
Installation of a gas pipe must comply with the Standard for
Decorative Gas Appliances for Installation in Vented Fireplaces,
ANSI Z21.60.
This fireplace is not designed to sit directly on a
combustible floor system. The Fire-Lite application of the
Magnum 86072 Series fireplace is an engineered system and
designed to be built upon a combustible floor system. The Fire-
Lite will also require a design that will support the total weight
of the Isokern fireplace and chimney system. The FTF-13 or
equivalent chimney system
only
must be used with the Fire-
Lite application. Contact the Technical Department at 800-642-
2920 for details.
This fireplace is intended for use as a supplemental
heat source only and is not intended for heavy use as a primary
heating system.
Overfiring, abusive burning or mistreatment will void
any claims (eg. burning construction debris or other highly
flammable material; tossing, kicking or otherwise forcing logs
into the firebox).
Magnum 86072 Series fireplaces and DM chimney
systems are conventional indoor or outdoor fireplaces designed
to appear like traditional masonry fireplaces. Magnum 86072
Series fireplace and DM chimney system units are intended
for installation in residential homes and other buildings of
conventional construction.
Note:
The local authority having code jurisdiction should be
consulted before installation to determine the need to obtain a
permit.
Important areas of concern with the installation of these
fireplaces are: construction of proper load bearing foundation
and concrete support slab; code required hearth extension
substrates and supports; proper assembly of components;
clearance to combustible materials; height of chimney; and,
techniques employed in applying finishing materials to the
fireplace opening and hearth extension.
Each of these important topics will be covered in detail
throughout this manual. Installation personnel must give special
attention to each topic as the installation progresses.
All work performed on, near and adjoining the fireplace
and chimney installation must meet or exceed the specifications
and requirements in this manual and the prevailing local
building code.
Subsequent renovations, additions of cabinets and
storage spaces in the enclosure surrounding the fireplace are
also limited to the specifications in this manual and to the
prevailing local building code.
Isokern is not responsible for other construction work
around the fireplace unit.
Содержание Magnum 86072-60
Страница 2: ......
Страница 40: ...40 DM Chimney System Lateral Support cont FIGURE 81 FIGURE 82 ...
Страница 55: ...55 Notes ...