Note:
The Magnum 86072 model 72 is designed to operate
with two flues. The top of the smoke dome allows for the
placement of two Isokern DM chimneys or two solid fuel listed
metal chimneys of the appropriate size.
Step 22:
Top plate part # 77A, two required, to be used “as is”.
(Figure 60)
Place the two top plate small components on top of
the second tier smoke dome arrangement so that they meet at
the centerline of the smoke dome. Typically, the outlet hole sits
closer to the back of the smoke dome. The top plates should sit
flush with the front and back of the smoke dome. (Figure 61).
The top width dimension of the completed smoke
dome should measure 64 1/2”. (Figure 58) Each top plate has
a width dimension of 32-3/4 inches. Two of the top plates
butted together should cover the smoke dome top with minor
overhang which is acceptable. The top plates should be flush
with the top sides of the smoke dome assembly.
Note:
Be sure to put Earthcore Mortar on the contact surfaces
of the vertical joints where the components connect. Look
for some mortar to squeeze out along the joints of all contact
surfaces as a sign that the joint is thoroughly sealed with the
approved mortar. Fill any and all gaps in the assembly, as
necessary, with the approved mortar.
FIGURE 59
FIGURE 60
FIGURE 61
Assembly Instructions - 86072-72 cont.