Assembly Instructions - 86072-72
The Magnum 86072 - 72 is a custom unit made of standard parts
that are cut and fitted together in the field. The following cut
and assembly instructions identify the parts by name and by
part number, the quantity required, the field cut dimensions for
each modified component and the placement of each part in the
assembly.
Note:
At all component placement, be sure to mortar all contact
surfaces with Earthcore Mortar. Check for complete sealing of
each contact joint while assembly progresses.
Step 1:
Base plate, Part # 91, two required . These pieces are
used “as is”, without any field cutting required.
Set the two # 91 base plate components on an appropriate
masonry foundation and positioned exactly where the firebox is
to sit. Set the two pieces so that the centerline of the grouping
is a butt joint. This makes for square ends at both the left and
right ends of the grouping. The overall length of the base plate
assembly should measure 85 1/2” and 28” inches deep. Figure
38)
Step 2:
Side wall, part # 60, eight pieces required, used “as is”.
The firebox side wall components are used without
modification. The side wall pieces stack four high on both the
left and right hand ends of the base plate arrangement (Figure 39)
The stack of four firebox side wall components will be
assembled in conjunction with the firebox back wall components
described in the following steps.
Step 3:
Back wall, part # 67, eight pieces required, four pieces to
be “field modified”.
Cut the tongue off one end of each of the four # 67 back
wall components. After cutting, each of these four cut pieces
should measure 38 1/2” from the cut end to the shoulder of the
un-altered end (Figure 40).
Step 4:
Back wall, part # 67, four pieces required, to be
“field modified”.
Cut one end of each of the four # 67 back wall
components. These four cut pieces should measure 34-1/2” from
the cut end to the shoulder of the un-altered end (Figure 41).
Step 5:
Build the Magnum 86072-72 firebox by setting a 38 1/2”
# 67 Back Wall (from Step 3) on the base plate with its tongue
end interlocked into the firebox side wall positioned at the end of
the base plate (Figure 42).
The square cut end of this 38 1/2” # 67 back wall
component should sit flush with the back of the base plate
with its cut end past the centerline butt joint in the base plate
arrangement. (Figure 42).
Note:
Be sure to put Earthcore Mortar on the contact surfaces of
the vertical joints where the components connect. Look for some
mortar to squeeze out along the joints of all contact surfaces
as a sign that the joint is thoroughly sealed with the approved
mortar. Fill any and all gaps in the assembly, as necessary, with
the approved mortar.
20
DISCAR
D
DISCAR
D
85 1/2”
38 1/2“
34 1/2”
FIGURE 38
FIGURE 39
FIGURE 40
FIGURE 41
FIGURE 42