![Isokern Magnum 86072-60 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/isokern/magnum-86072-60/magnum-86072-60_installation-operation-and-owners-manual_2093413022.webp)
22
The damper support pair at the front of the firebox
opening will be set into the 4” x 6” steel angle from Step 7
(Figure 48).
Since the inside corner of the steel angle is rounded, it
is a good idea to round the bottom front corner of the damper
support to match the steel.
With the bevel cut ends of the damper support pairs
meeting at the middle of the firebox, the bevel joint should be an
even and good fit. The damper supports overall installed length
should be 85 1/2”.
Notes:
A.
Do not join the damper supports with a butt joint. The bevel
joint discussed above is the REQUIRED type of joint for the
damper support.
B.
The bevel angle of 15˚ is a convenient angle and is given as a
suggested angle. The angle of bevel could be different just so the
angles cut in the adjoining damper supports join.
Step 11:
Damper support (left), part M64L and damper support
(right), part M64R, one each required. To be used “as is”.
Set the damper support (left) and the damper support
(right) into place on top of the firebox side walls in between the
front and rear damper supports.
Each of the damper supports, right and left, is designed
specifically for its own side of the unit. When properly set, each
damper plate side piece sits flush with the outside face of the
firebox side wall. The interior bottom edge of the damper support
end pieces align with the angle of the interior of the firebox side
wall (Figures 48 & 49).
For the Magnum 86072-72 the smoke dome components
stack two tiers high giving a smoke dome of approximately 32
inches in height.
Step 12:
Smoke dome top large, part 13, six required, to be “field
modified”; smoke dome top medium, part 11, two required, to
be “field modified”; smoke dome top sloping, part 34, four (4)
required, to be used “as is”.
Begin building the Magnum 86072-72 fireplace smoke
dome by cutting the haunch off of one end of each of the four
smoke dome top large components, part 13. After cutting the
bottom length of the piece will be 49 3/4”.
When cutting the haunch off be sure to follow the angle
of the sloping end in order to get the proper slope angle to the cut
(Figure 50).
Note:
Be sure to put Earthcore Mortar on the contact surfaces of
the vertical joints where the components connect. Look for some
mortar to squeeze out along the joints of all contact surfaces
as a sign that the joint is thoroughly sealed with the approved
mortar. Fill any and all gaps in the assembly, as necessary, with
the approved mortar.
Assembly Instructions - 86072-72 cont.
85 ½”
35 3/4”
DISCAR
D
49 3/4”
DISCAR
D
35 3/4”
49 3/4”
85 ½”
#13
#13
#13
#13
FIGURE 48
FIGURE 49
FIGURE 50
FIGURE 51
FIGURE 52