Goodrive350-UL Series VFD
Extension cards
-307-
LED
Color
State
Description
LED1
Green
3.3V power indicator
LED2
(Bus state indicator)
Red
On
No network connection
Blinking
The connection to the PROFINET
controller through a network cable is
OK, but the communication is not
established.
Off
Communication with the PROFINET
controller has been established
LED3
(System fault indicator)
Green
On
PROFINET diagnosis is enabled
Off
PROFINET diagnosis is not enabled
LED4
(Slave ready indicator)
Green
On
TPS-1 protocol stack has started
Blinking
TPS-1 waits for MCU initialization
Off
TPS-1 protocol stack does not start
LED5
(Maintenance state
indicator)
Green
Manufacturer-specific––depending on
the characteristics of the device
LED6/7
(Network port state
indicator)
Green
On
PROFINET communication card and
PC/PLC have been connected through
a network cable.
Off
PROFINET communication card and
PC/PLC have not been connected.
LED8/9
(Network port
communication
indicator)
Green
On
PROFINET communication card and
PC/PLC are communicating.
Off
PROFINET communication card and
PC/PLC are not communicating.
Electrical connection:
The PROFINET communication card adopts a standard RJ45 interface and can adopt the linear
network topology or star network topology. The electrical connection in linear network topology mode
is shown in the following.
Master
device
Slave device 2
RJ45
RJ45
Slave device 1
RJ45
RJ45
Slave device n
RJ45
RJ45
Electrical connection in linear network topology mode
Note:
For the star network topology, users need to prepare PROFINET switches.
The electrical connection in start network topology mode is shown in the following.
Содержание GD350-004G-2-UL