Goodrive350-UL Series VFD
Function parameter list
-189-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
P10.32
Multi-step speed
15
Terminal 1 OFF ON
OFF
ON
OFF
ON
OFF
ON
Terminal 2 OFF OFF
ON
ON
OFF OFF
ON
ON
Terminal 3 OFF OFF OFF OFF
ON
ON
ON
ON
Terminal 4 OFF OFF OFF OFF OFF OFF OFF OFF
Step
0
1
2
3
4
5
6
7
Terminal 1 OFF ON
OFF
ON
OFF
ON
OFF
ON
Terminal 2 OFF OFF
ON
ON
OFF OFF
ON
ON
Terminal 3 OFF OFF OFF OFF
ON
ON
ON
ON
Terminal 4 ON
ON
ON
ON
ON
ON
ON
ON
Step
8
9
10
11
12
13
14
15
0.0%
○
P10.33
Running time of
15
th
step
0.0s(min)
○
P10.34
Acceleration/dec
eleration time of
0
th
–7
th
step of
simple PLC
Detailed illustration is shown in the table below.
Function
code
Binary
Step
number
ACC/
DEC
time 1
ACC/
DEC
time 2
ACC/
DEC
time 3
ACC/
DEC
time 4
P10.34
BIT1
BIT0
0
00
01
10
11
BIT3
BIT2
1
00
01
10
11
BIT5
BIT4
2
00
01
10
11
BIT7
BIT6
3
00
01
10
11
BIT9
BIT8
4
00
01
10
11
BIT11 BIT10
5
00
01
10
11
BIT13 BIT12
6
00
01
10
11
BIT15 BIT14
7
00
01
10
11
P10.35
BIT1
BIT0
8
00
01
10
11
BIT3
BIT2
9
00
01
10
11
BIT5
BIT4
10
00
01
10
11
BIT7
BIT6
11
00
01
10
11
BIT9
BIT8
12
00
01
10
11
BIT11 BIT10
13
00
01
10
11
BIT13 BIT12
14
00
01
10
11
BIT15 BIT14
15
00
01
10
11
Select corresponding acceleration/deceleration time,
and then convert 16-bit binary number into
hexadecimal number, finally, set corresponding
function code.
Acceleration/deceleration time 1 is set by P00.11
and P00.12; Acceleration/deceleration time 2 is set
by P08.00 and P08.01; Acceleration/deceleration
0x0000
○
P10.35
Acceleration/dec
eleration time of
8
th
– 15
th
step of
simple PLC
0x0000
○