Goodrive350-UL Series VFD
Function parameter list
-216-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
filter width
The filtering time is P20.18×0.25 μs. The value 0 or 1
indicates 0.25 es.
P20.19
Pulse reference
filter width
0–63
The filtering time is P20.18×0.25 μs. The value 0 or 1
indicates 0.25 μs.
10
○
P20.20
Pulse number of
pulse reference
0–65535
1024
◎
P20.21
Enable angle
compensation of
synchronous
motor
0–1
0
○
P20.22
Switch-over
frequency
threshold of
speed
measurement
mode
0–630.00Hz
Note:
This parameter is valid only when P20.12 is
set to 0.
1.00Hz
○
P20.23
Synchronous
motor angle
compensation
coefficient
-200.0–200.0%
100.0%
○
P20.24
Reserved
variable
0–65535
0
○
P21 group Position control
P21.00 Positioning mode
Ones: Control mode selection
0: Speed control
1: Position control
Tens: Position command source
0: Pulse string
1: Digital position
2: Positioning of photoelectric switch during stop
Hundreds: Position feedback source (reserved, fixed
to channel P)
0: PG1
1: PG2
Thousands: servo mode
Bit0: Position deviation mode
0: No deviation
0x0000
○