RS-1600-X24 User Guide
80
7.15.2 Errors
Error events let you know that something related to the X24 Subsystem, module, or disk drives has failed
and requires immediate attention.
Table 7–5
defines each error event and recommends the action you
should take.
SYS OFFLINE
FAIL
The system attempted to use Put
Offline on an SM, but the request was
rejected, probably because availability
to the hosts would have been affected.
This Put Offline request may occur
when you press one of the module
latches to remove the module. In this
case, we recommend that you do not
take the module offline.
SYS ONLINE FAIL The system attempted to Put Online a
newly inserted module, however the
Put Online request failed.
The event gives a reason why the Put
Online failed. Examine this reason and
take the appropriate action. If the
reason is DIAGNOSTIC FAIL, a
hardware problem was found with the
module. In this case, try replacing the
module with a different one.
UNWRITABLE
CACHE
The SDRAM cache has battery
backed-up data, and the arrays
assigned to this data are not present.
Either determine which drives are
missing and reinstall them, or select
Yes
when asked if you want to discard
this data.
VOLT/TEMP
WARN
The analog-to-digital convertor
monitored a temperature or voltage in
the warning range.
Check that the X24 Subsystem’s fans
are running. Check that the ambient
temperature is not too warm. Check for
any obstructions to the air flow. See
, ”Array Basics”, on page 89
.
Table 7–4
Warning events (Continued)
Event
Definition
Recommended Action
Table 7–5
Error events
Event
Definition
Recommended Action
ARRAY
CRITICAL
One drive in the specified array
failed and the array is running in
degraded mode (not fault tolerant).
Replace the failed drive and add it as a
spare to the critical array. If you have
dynamic spares enabled, you only need
to replace the drive. The system will
automatically reconstruct the array.
BATTERY
FAILED
A failure in the battery pack or
charging interface has been
detected.
Check that the battery is firmly connected
to the SM module. Refer to the
X24
Subsystem Getting Started Guide
.
Replace the battery.
DISK CHAN
FAILED
An error has occurred in
communicating on the disk channel.
Check the cables on the channel.
Содержание RS-1600-X24
Страница 1: ...RS 1600 X24 User Guide Part No 43061 01A Issue 1 0 June 23 2003 ...
Страница 9: ...Contents ix Index 229 ...
Страница 10: ...x RS 1600 X24 User Guide ...
Страница 19: ...Introduction 1 Chapter 1 Introduction 1 1 The RS 1600 X24 System Figure 1 1 The RS 1600 X24 FC AL System ...
Страница 50: ...RS 1600 X24 User Guide 32 ...
Страница 56: ...RS 1600 X24 User Guide 38 ...
Страница 70: ...RS 1600 X24 User Guide 52 ...
Страница 112: ...RS 1600 X24 User Guide 94 ...
Страница 170: ...RS 1600 X24 User Guide 152 ...
Страница 190: ...RS 1600 X24 User Guide 172 ...
Страница 206: ...RS 1600 X24 User Guide 188 ...
Страница 230: ...RS 1600 X24 User Guide 212 ...
Страница 238: ...RS 1600 X24 User Guide 220 ...
Страница 246: ...RS 1600 X24 User Guide 228 ...