Introduction
5
1.3.1.1
Multiple Power Supply/Cooling Modules
The RS-1600-X24 system must always be operated with two Power Supply/Cooling modules fitted. The
two Power Supply/Cooling modules operate together so that if one fails the other maintains the power
supply and cooling while you replace the faulty unit.
Module replacement should only take a few minutes to perform but must be completed within 5 minutes
from removal of the failed module.
1.3.2 Operators Panel
Supplied as an integral part of the Enclosure core product, a typical Operators (Ops) Panel is shown in
Figure 1–6
.
The Ops Panel provides the enclosure with a micro controller which is used to monitor and control all
elements of the Enclosure.
1.3.2.1
Ops Panel Indicators and Switches
The Ops Panel includes Light Emitting Diodes (LEDs) which show the status for all modules, an Audible
Alarm which indicates when a fault state is present, a push-button Alarm Mute switch and a thumb wheel
SEL_ID address Range selector switch.
The Ops Panel switch functions are shown in
Table 1–1
.
Important
Switch settings are only read at Power On.
The X24 enclosure ID must always be set to select ID1.
Figure 1–6
Operators (Ops) Panel
Содержание RS-1600-X24
Страница 1: ...RS 1600 X24 User Guide Part No 43061 01A Issue 1 0 June 23 2003 ...
Страница 9: ...Contents ix Index 229 ...
Страница 10: ...x RS 1600 X24 User Guide ...
Страница 19: ...Introduction 1 Chapter 1 Introduction 1 1 The RS 1600 X24 System Figure 1 1 The RS 1600 X24 FC AL System ...
Страница 50: ...RS 1600 X24 User Guide 32 ...
Страница 56: ...RS 1600 X24 User Guide 38 ...
Страница 70: ...RS 1600 X24 User Guide 52 ...
Страница 112: ...RS 1600 X24 User Guide 94 ...
Страница 170: ...RS 1600 X24 User Guide 152 ...
Страница 190: ...RS 1600 X24 User Guide 172 ...
Страница 206: ...RS 1600 X24 User Guide 188 ...
Страница 230: ...RS 1600 X24 User Guide 212 ...
Страница 238: ...RS 1600 X24 User Guide 220 ...
Страница 246: ...RS 1600 X24 User Guide 228 ...