System Configuration
47
5.9 Rescanning All Ports
You can tell the X24 Subsystem to scan all disk ports for new or removed disk drives. You can use this
option when you install or remove disk drives. The rescan temporarily pauses all I/O processes, then
resumes normal operation.
If you are using an enclosure with an EMP, the X24 Subsystem performs a rescan automatically. With an
EMP, the EMP detects the change in drive status and updates the X24 Subsystem about removed drives
almost immediately; however, installed drives will be detected after a three-minute delay. This delay is to
allow the new drives to spin up.
To rescan all ports:
1
From SAM, select
Manage X24 Subsystem > Utilities
.
The
Rescan
page displays.
2
Click
Rescan
.
5.10 Pausing I/O
Most drive enclosures allow you to remove and replace drives while FC device port activity continues.
However, you may still want to pause I/O if you are replacing more than one disk drive. The Hot Swap
Pause option suspends activity on all device channels used in the X24 Subsystem, thereby ensuring data
integrity on the connected drives and arrays.
Caution
Pausing I/O halts active I/O to the host.
Note
If you are not sure that your enclosure supports hot swapping, use the Hot Swap Pause option before
you remove or replace any drives in an array.
To pause I/O:
1
From SAM, select
Manage X24 Subsystem > Utilities > Hot Swap Pause
.
The
Hot Swap Pause
page displays.
2
Click
Pause
.
3
When you have replaced the drive, resume I/O activity by clicking
Unpause
.
Caution
Do not stay in the Hot Swap Pause mode for too long; otherwise, an operating system time-out may occur
(the time varies according to the operating system). For example, in Windows NT, the default limitation
during I/O activity is 10 seconds.
Содержание RS-1600-X24
Страница 1: ...RS 1600 X24 User Guide Part No 43061 01A Issue 1 0 June 23 2003 ...
Страница 9: ...Contents ix Index 229 ...
Страница 10: ...x RS 1600 X24 User Guide ...
Страница 19: ...Introduction 1 Chapter 1 Introduction 1 1 The RS 1600 X24 System Figure 1 1 The RS 1600 X24 FC AL System ...
Страница 50: ...RS 1600 X24 User Guide 32 ...
Страница 56: ...RS 1600 X24 User Guide 38 ...
Страница 70: ...RS 1600 X24 User Guide 52 ...
Страница 112: ...RS 1600 X24 User Guide 94 ...
Страница 170: ...RS 1600 X24 User Guide 152 ...
Страница 190: ...RS 1600 X24 User Guide 172 ...
Страница 206: ...RS 1600 X24 User Guide 188 ...
Страница 230: ...RS 1600 X24 User Guide 212 ...
Страница 238: ...RS 1600 X24 User Guide 220 ...
Страница 246: ...RS 1600 X24 User Guide 228 ...