MorphoWave
TM
OEM
– Installation guide
Annex 1 : Maintenance
94
IDEMIA
D
OCUMENT
–
R
EPRODUCTION AND
D
ISCLOSURE
F
ORBIDDEN
2015_2000009096 V6
January 2019
MorphoWave
TM
Desktop change procedure
To replace the MorphoWave
TM
Desktop sensor:
Turn off the entire system (MorphoAccess Sigma Wave, MorphoWave
TM
Desktop,
PC Wave, Ethernet switch).
Unplug the USB 3.0 connector of the MorphoWave
TM
Desktop connected to the PC.
Unplug the external power supply of the MorphoWave
TM
Desktop.
Connect to the PC the new MorphoWave
TM
Desktop sensor on the same USB 3.0
PC port.
Connect its external power supply.
Turn on the whole system.
Once the boot procedure is finished (boot time may take several minutes depending
of the database size) the MorphoWave
TM
Desktop shall have green lighting on and
identification will work if at least one user is in database.
PC Wave change procedure
To replace the PC on MorphoWave
TM
OEM system:
On the MorphoAccess Sigma Wave, follow the unpairing procedure (step 1 and 2)
to disassociate the sensor.
Turn off the entire system.
Connect the new PC: power supply, USB 3.0 connection with FOTF, Ethernet
connection with Ethernet switch.
Turn on the whole system and follow the pairing procedure.
Once the boot procedure is finished (boot time may take several minutes depending
of the database size) the MorphoWave
TM
Desktop shall have green lighting on and
identification will work if at least one user is in database.
MorphoAccess Sigma Wave change procedure
To replace the MorphoAccess Sigma Wave on MorphoWave
TM
OEM system:
On the PC follow steps 1, 4 & 5 of the unpairing procedure.
Delete “Pair_Certificate.data” in explorer window.
Turn off the entire system.
Connect the new MorphoAccess Sigma Wave reference: power supply, Ethernet
connection with Ethernet switch.
Turn on the system.
Once the boot procedure is finished, follow MorphoAccess Sigma Wave installation
procedure. One enrolment has to be performed prior to get the MorphoWave
TM
Desktop sensor turned on.