Cabling
Cable for wiring shall be AWG 20 to 24, length shall be 12 cm to 15 cm (stripped on
0,6mm).
Figure 12: Cabling preparation
Prefer rigid cable to flexible cable (easier to connect)
Connection details:
Characteristics
min
max
Conductor cross section solid or stranded
0.2 mm² 0.5 mm²
Conductor cross section stranded, with ferrule without plastic
sleeve
0.25
mm²
0.5 mm²
Conductor cross section AWG/kcmil
24
20
Closing
Don’t forget to insert battery before closing product, but power has to be set up just
after closing it. If product has to be stored, don’t forget to remove the battery.
Lock the product with the lower screw.
6mm
12-1
5cm