MorphoWave
TM
OEM
– Installation guide
Section 3 :Installation Procedure
52
IDEMIA
D
OCUMENT
–
R
EPRODUCTION AND
D
ISCLOSURE
F
ORBIDDEN
2015_2000009096 V6
January 2019
5
LED1
In
Wiegand LED IN 1 (option) : panel
feedback
(Output type required: Open drain or
5V+/-5%)
6
LED2
In
Wiegand LED IN 2 (option) : panel
feedback
(Output type required: Open drain or
5V+/-5%)
Figure 28: Wiegand output wiring (Revision 2)
20 Black / Red Digital ground
Ground for Wiegand
24 Green
D0_OUT
Out Wiegand OUT D0 (5V TTL)
21 White
D1_OUT
Out Wiegand OUT D1 (5V TTL)
25 Blue
LED1
In
Wiegand LED IN 1 (option) : panel feedback
(Output type required: Open drain or 5V+/-5%)
26 Blue / Red LED2
In
Wiegand LED IN 2 (option) : panel feedback
(Output type required: Open drain or 5V+/-5%)
The use of LED1 and LED2 wires is described in the paragraphs below.
The controller supports neither LED1 nor LED2 signals
When the access controller has no relay contact to provide an answer to the
MorphoAccess Sigma Wave terminal, then the decision to emit either the “access
granted” signal or the “access denied” signal is taken by another way. It is either the
MorphoAccess Sigma Wave terminal itself that decide, or it waits for the access
controller answer through the local area network (TCP), or on the serial port in (RS422).
It is strongly recommended to disable the LED IN feature, to avoid any interference on
MorphoAccess Sigma Wave terminal behavior.