MorphoWave
TM
OEM
– Installation guide
Section 3 : Installation Procedure
2015_2000009096 V6
January 2019
IDEMIA
D
OCUMENT
–
R
EPRODUCTION AND
D
ISCLOSURE
F
ORBIDDEN
45
Power Supply
POE and external power supply are not used at the same time: if both power supplies
are used, priority is given to external power supply. If external power supply is shut
down, switch to POE without reboot is not guarantee.
External Power supply
Figure 16: Power supply wiring (Initial version)
A
1
Power Supply 12V
In
Positive 12 Volts, power supply
2
Power ground
In
Ground power supply
Figure 17: Power supply wiring (Revision 2)
1
Red
Power Supply 12V
In
Positive 12 Volts, power supply
2
Black
Power ground
In
Ground power supply
External power supply
Must comply with CEE/IEC EN60950 standard.
12V to 24V (regulated) 1 Amp min at 12V.
Could be provided by a 12 Volts Wiegand power supply, which complies with the
Security Industry Association's Wiegand standard March 1995.
Inversion of +12V and GND will damage the product
1
6
1
6
1
6
1
6
A
B
C
D