background image

Disclaimer:

Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor

reserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed are

correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

TECHNICAL DETAILS

Mains Water supply inlet

1” BSP Female Thread

Pump Connection

1” BSP Female Thread

Water Outlet Connection

1” BSP Female Thread

Protective Rating

IP44

Min Mains Pressure

100 kPa

Max Mains Pressure

1000 kPa

Water Temp Range

1°C - 40°C

Ambient Temp Range

1°C - 40°C

Rated Supply Voltage

230 - 240Vac

Max Electrical Load

10A

Power Consumption (Mains)

1W

Power Consumption (Tank)

18W

Minimum Flow Rate

2 L/min

PRODUCT OVERVIEW / APPLICATION

The Vada Rain2Main is designed to select between stored rainwater 

(when available) and mains supply water, and send this water to 

your toilet cistern, washing machine, garden and other non-potable 

household water applications. It features automatic pump control to 

minimise the use of electricity while saving water. 

When your tank is empty, the Rain2Main seamlessly switches to 

mains water supply so that there is no interruption of water to your 

toilet cistern or washing machine. 

Do not use the Rain2Main for liquids other than clean water.

WARRANTY & AFTER SALES SERVICE

You have purchased a quality product from Reece Australia. This 

product is covered by a 24 month warranty. This warranty covers faults 

in the product construction, material and assembly. Faulty products 

will be repaired or exchanged free of charge. Faulty items become our 

property.

This warranty does not include faults caused by

• 

Unsuitable or improper use

• 

Incorrect installation

• 

Normal wear and tear

• 

Inadequate or complete lack of maintenance

• 

Chemical, electrochemical or electrical influences

To the maximum extent permitted by law, Reece excludes all warranties 

other than those set out above. In the event of a warranty claim, we 

will replace or repair defective products, or pay for the cost of having 

defective products repaired or replaced, but will not be liable for any 

injury to any person, damage to any property, any indirect or 

consequential loss, or in any other respect.

For after sales service, call 1800 080 055.

VADA - Rain2Main Automatic Rainwater Controller

INSTALLATION INSTRUCTIONS

• 

The operator must be provided with this owner’s manual. This 

must be read before instlalation and followed during installation.

• 

 These instructions are a guide only. Users not familiar with the 

installation and maintenance of electrical and pumping equipment 

should seek advice from people with experience in pump installa-

tion and operation.

          Rain2Main is designed to be used with clean water in a 

          residential application. Do not use with alternative fluids, 

          specifically abrasive, corrosive or explosive fluids.

    

          This appliacne is not intended for use by persons (incl children)

          with reduced physical, sensory or mental capabilities, or lack of 

          experience or knowledge, unless have been given supervision 

          or instruction concerning the use of the appliance. Children 

          should be supervised to ensure they do not play with Rain2Main.

Отзывы: