MorphoWave
TM
OEM wiring
At this stage all component have been prepared, it is time to connect devices together.
Material required (not included):
-
Ethernet cable : 3 (2 in 1 for network connectivity)
-
Power supply or Power Over Ethernet for MorphoAccess Sigma
Installation procedure
Components wiring requires to not connect power supply of devices during this
operation.
Connect on the PC the biometric sensor on a USB 3.0 port (blue internal socket).
Connect on the PC the RJ45 cable.
Connect on the PC the power wire of the power adapter.
Connect RJ45 cables on the Ethernet switch.
o
1 port is dedicated for the RJ45 cable coming from the PC (“PC Wave”).
o
1 port is dedicated for the RJ45 cable coming from the MorphoAccess
Sigma Wave (“MAsigma”).
o
1 port is optional and dedicated for customer network connection
(“External”).
o
Please do not use the 2 other ports which are reserved for maintenance
purpose only.