OEM displays sensor error message
Following screen may appear if a connection issue is encountered between the PC and
the MorphoWave
TM
Desktop:
Please follow these steps to recover the system:
-
Check the USB 3.0 connection between the MorphoWave
TM
Desktop and
the PC. The cable has to be plugged on a USB 3.0 port (blue socket inside).
-
Check PC is properly working and check power supply connections.
-
If these steps do not solve the issue, please call the support.
MorphoWave
TM
OEM displays sensor power error message
Following screen may appear if a power issue is on the MorphoWave Desktop:
Please follow these steps to recover the system:
-
Check the power supply is connected on the MorphoWave
TM
Desktop.
-
Check if the green LED on the power adaptor indicates that it works.
-
Restart the MorphoWave
TM
OEM.
-
If the message is displayed again after restart, please request to change the
power supply unit.
-
Once the power supply unit is changed, restart the entire system to recover
a working MorphoWave
TM
.
-
If these steps do not solve the issue, please call the support.