MorphoWave
TM
OEM
– Installation guide
Section 3 :Installation Procedure
50
IDEMIA
D
OCUMENT
–
R
EPRODUCTION AND
D
ISCLOSURE
F
ORBIDDEN
2015_2000009096 V6
January 2019
Operating principle for the Integrator Tamper Switch
This tamper switch is for Integrator who wants to inform the MorphoAccess Sigma
Wave when the Integrator mechanical box is tampered.
When the contact state is changed from close to open, the MorphoAccess Sigma
Wave executes all actions configured in case of tamper.
Wiegand input wiring
Figure 25: Wiegand input wiring (Initial version)
A
5
Digital ground
Ground for Wiegand (connect pin 5 or 6)
6
Digital ground
Ground for Wiegand (connect pin 5 or 6)
B
1
D0_IN
In
Wiegand IN D0
(Output type required: Open drain or
5V+/-5%)
2
D1_IN
In
Wiegand IN D1
(Output type required: Open drain or
5V+/-5%)
C
4
LED0
Out
Wiegand LED OUT 1 (typical = 5V)
(option) :
1
6
1
6
1
6
1
6
A
B
C
D