MorphoWave
TM
OEM
– Installation guide
Section 3 :Installation Procedure
54
IDEMIA
D
OCUMENT
–
R
EPRODUCTION AND
D
ISCLOSURE
F
ORBIDDEN
2015_2000009096 V6
January 2019
Serial port wiring
DataClock Input
Figure 29: Serial port wiring – DataClock (Initial version)
A
5
Digital ground
Ground for Wiegand (connect pin 5 or 6)
6
Digital ground
Ground for Wiegand (connect pin 5 or 6)
B
1
D0_IN
In
Data (Output type required: Open drain
or 5V+/-5%)
2
D1_IN
In
Clock (Output type required: Open drain
or 5V+/-5%)
C
4
Digital Output 0
Out
Card present signal (if configured, only
one selectable for Morpho Legacy)
5
Digital Output 1
Out
Card present signal (if configured)
6
Digital Output 2
Out
Reserved
Figure 30: Serial port wiring – DataClock (Revision 2)
20 Black / Red
Digital ground
Ground for Wiegand
22 Green / Red
D0_IN
In
Data (Output type required: Open
drain or 5V+/-5%)
23 White / Red
D1_IN
In
Clock (Output type required: Open
drain or 5V+/-5%)
1
6
1
6
1
6
1
6
A
B
C
D