Error
code
Description
Action
1803
No
more
memory
(above
1
MB
for
a
PCI
or
PCI
Express
adapter).
1.
Make
sure
that
the
settings
for
the
adapter
and
all
other
adapters
in
the
Configuration/Setup
Utility
program
are
correct.
2.
If
the
error
code
indicates
a
particular
PCI
or
PCI
Express
slot
or
device,
remove
that
device.
3.
Reseat
each
adapter.
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Adapter
b.
(Trained
service
technician
only)
System
board
1804
No
more
memory
(below
1
MB
for
a
PCI
or
PCI
Express
adapter).
1.
Make
sure
that
the
settings
for
the
adapter
and
all
other
adapters
in
the
Configuration/Setup
Utility
program
are
correct.
2.
If
the
error
code
indicates
a
particular
PCI
or
PCI
Express
slot
or
device,
remove
that
device.
3.
Reseat
each
adapter.
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Adapter
b.
(Trained
service
technician
only)
System
board
1805
PCI
option
ROM
checksum
error.
1.
Remove
the
failing
adapter.
2.
Reseat
each
adapter.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Failing
adapter
b.
(Trained
service
technician
only)
System
board
1806
PCI
built-in
self-test
(BIST)
failure
occurred.
1.
Make
sure
that
the
settings
for
the
adapter
and
all
other
adapters
in
the
Configuration/Setup
Utility
program
are
correct.
2.
If
the
error
code
indicates
a
particular
PCI
or
PCI
Express
slot
or
device,
remove
that
device.
3.
Reseat
each
adapter.
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Adapter
b.
(Trained
service
technician
only)
System
board
22
IBM
System
x3105
Type
4347:
Problem
Determination
and
Service
Guide
Содержание x3105 - System - 4347
Страница 1: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 18: ...xvi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 30: ...12 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 70: ...52 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 114: ...96 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 123: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix B Notices 105...
Страница 124: ...106 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 129: ......
Страница 130: ...Part Number 43W7037 Printed in USA 1P P N 43W7037...