To
remove
the
power
supply,
complete
the
following
steps.
1.
Read
the
safety
information
that
begins
on
page
vii
and
“Installation
guidelines”
on
page
59.
2.
Turn
off
the
server
and
all
peripheral
devices;
then,
disconnect
the
power
cords
and
all
external
cables.
3.
Remove
the
cover
(see
“Removing
the
cover”
on
page
61).
Note:
It
might
be
helpful
to
lay
the
server
on
its
right
side
for
the
remainder
of
this
procedure.
4.
Disconnect
the
cables
from
the
power
supply
to
the
system
board
and
all
internal
components.
5.
To
provide
extra
space
for
the
power-supply
removal,
use
the
following
procedure:
v
Slide
the
drives
in
bay
1
and
bay
2
(if
any
are
installed)
forward
slightly
(see
“Removing
a
CD
or
DVD
drive”
on
page
72
for
more
information).
It
is
not
necessary
to
remove
these
drives.
v
Lift
the
microprocessor
air
baffle
out
of
the
server.
v
Remove
the
microprocessor
heat
sink
(see
“Removing
the
microprocessor
and
heat
sink”
on
page
86).
It
is
not
necessary
to
remove
the
microprocessor.
v
Remove
any
DIMMs
in
DIMM
connectors
3
and
4
(see
“Removing
a
memory
module”
on
page
67).
6.
Remove
the
four
screws
that
secure
the
power
supply
to
the
chassis.
7.
Slide
the
power
supply
toward
the
front
of
the
chassis
until
it
clears
the
mounting
bracket;
then,
tilt
the
power
supply
toward
the
system
board
and
carefully
pull
it
out
of
the
server.
8.
If
you
are
instructed
to
return
the
power
supply,
follow
all
packaging
instructions,
and
use
any
packaging
materials
for
shipping
that
are
supplied
to
you.
84
IBM
System
x3105
Type
4347:
Problem
Determination
and
Service
Guide
Содержание x3105 - System - 4347
Страница 1: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 18: ...xvi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 30: ...12 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 70: ...52 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 114: ...96 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 123: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix B Notices 105...
Страница 124: ...106 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 129: ......
Страница 130: ...Part Number 43W7037 Printed in USA 1P P N 43W7037...