v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
System
x3105
Type
4347,”
on
page
53
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
106
A
diskette
controller
failure
occurred.
1.
Make
sure
that
the
Configuration/Setup
Utility
program
correctly
reflects
the
type
of
diskette
drive
that
is
installed.
2.
Reseat
the
following
components:
a.
Diskette
drive
cable
b.
Diskette
drive
3.
Replace
the
following
components
one
at
a
time
in
the
order
shown,
restarting
the
server
each
time:
a.
Diskette
drive
cable
b.
Diskette
drive
c.
(Trained
service
technician)
System
board
151
Real-time
clock
error.
1.
Reseat
the
battery.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
161
Real-time
clock
battery
error
occurred.
1.
Reseat
the
battery.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
162
Device
configuration
error
occurred.
1.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
and
save
the
settings.
2.
Reseat
the
following
components:
a.
Battery
b.
Failing
device
(if
the
device
is
a
FRU,
the
device
must
be
replaced
by
a
trained
service
technician
only)
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
Failing
device
(if
the
device
is
a
FRU,
the
device
must
be
replaced
by
a
trained
service
technician
only)
c.
(Trained
service
technician
only)
System
board
Chapter
2.
Diagnostics
17
Содержание x3105 - System - 4347
Страница 1: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 18: ...xvi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 30: ...12 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 70: ...52 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 114: ...96 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 123: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix B Notices 105...
Страница 124: ...106 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 129: ......
Страница 130: ...Part Number 43W7037 Printed in USA 1P P N 43W7037...