Error
code
Description
Action
001-250-00n
ECC
test
logic
failed.
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
(Trained
service
technician)
Replace
the
failing
microprocessor.
011-xxx-000
Failed
COM1
serial
port
test.
(Trained
service
technician
only)
Replace
the
system
board.
015-xxx-001
Failed
USB
test.
(Trained
service
technician
only)
Replace
the
system
board.
015-xxx-198
USB
device
connected
during
USB
test.
1.
Remove
all
USB
devices
and
run
the
test
again.
2.
(Trained
service
technician
only)
Replace
the
system
board.
020-xxx-000
Failed
PCI
Interface
test.
(Trained
service
technician
only)
Replace
the
system
board.
201-xxx-0nn
Failed
memory
test;
nn
=
slot
number
of
failing
DIMM.
1.
Reseat
the
DIMM
in
slot
nn
.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
DIMM
in
slot
nn
b.
(Trained
service
technician
only)
System
board
201-xxx-n99
Multiple
DIMM
failure;
n
=
bank
number
of
failing
pair.
1.
See
the
error
text
to
identify
the
failing
DIMMs.
2.
Reseat
the
DIMMs
in
bank
nn
.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
DIMMs
in
bank
nn
b.
(Trained
service
technician
only)
System
board
201-198-xxx
Memory
test
aborted.
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
program.
4.
Refer
to
the
error
log
for
additional
information.
201-199-xxx
Unexpected
error.
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
program.
4.
Refer
to
the
error
log
for
additional
information.
Chapter
2.
Diagnostics
43
Содержание x3105 - System - 4347
Страница 1: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 18: ...xvi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 30: ...12 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 70: ...52 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 114: ...96 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 123: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix B Notices 105...
Страница 124: ...106 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 129: ......
Страница 130: ...Part Number 43W7037 Printed in USA 1P P N 43W7037...