Solving
SCSI
problems
Note:
This
information
also
applies
to
Serial
Attached
SCSI
(SAS)
problems.
For
any
SCSI
error
message,
one
or
more
of
the
following
devices
might
be
causing
the
problem:
v
A
failing
SCSI
device
(adapter,
drive,
or
controller)
v
An
incorrect
SCSI
termination
jumper
setting
v
Duplicate
SCSI
IDs
in
the
same
SCSI
chain
v
A
missing
or
incorrectly
installed
SCSI
terminator
v
A
defective
SCSI
terminator
v
An
incorrectly
installed
cable
v
A
defective
cable
For
any
SCSI
error
message,
follow
these
suggested
actions
in
the
order
in
which
they
are
listed
until
the
problem
is
solved:
1.
Make
sure
that
external
SCSI
devices
are
turned
on
before
you
turn
on
the
server.
2.
Make
sure
that
the
cables
for
all
external
SCSI
devices
are
connected
correctly.
3.
If
an
external
SCSI
device
is
attached,
make
sure
that
the
external
SCSI
termination
is
set
to
automatic.
4.
Make
sure
that
the
last
device
in
each
SCSI
chain
is
terminated
correctly.
5.
Make
sure
that
the
SCSI
devices
are
configured
correctly.
Solving
power
problems
Power
problems
can
be
difficult
to
solve.
For
example,
a
short
circuit
can
exist
anywhere
on
any
of
the
power
distribution
buses.
Usually,
a
short
circuit
will
cause
the
power
subsystem
to
shut
down
because
of
an
overcurrent
condition.
To
diagnose
a
power
problem,
use
the
following
general
procedure:
1.
Turn
off
the
server
and
disconnect
all
ac
power
cords.
2.
Make
sure
that
the
ac
power-supply
voltage
switch
on
the
rear
of
the
server
is
set
to
the
correct
voltage
(115
V
ac
or
230
V
ac)
for
your
geography.
3.
Check
for
loose
cables
in
the
power
subsystem.
Also
check
for
short
circuits,
for
example,
if
a
loose
screw
is
causing
a
short
circuit
on
a
circuit
board.
4.
Remove
the
adapters
and
disconnect
the
cables
and
power
cords
to
all
internal
and
external
devices
until
the
server
is
at
the
minimum
configuration
that
is
required
for
the
server
to
start
(see
“Solving
undetermined
problems”
on
page
50
for
the
minimum
configuration).
5.
Reconnect
all
ac
power
cords
and
turn
on
the
server.
If
the
server
starts
successfully,
replace
the
adapters
and
devices
one
at
a
time
until
the
problem
is
isolated.
If
the
server
does
not
start
from
the
minimum
configuration,
replace
the
components
in
the
minimum
configuration
one
at
a
time
until
the
problem
is
isolated.
48
IBM
System
x3105
Type
4347:
Problem
Determination
and
Service
Guide
Содержание x3105 - System - 4347
Страница 1: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 18: ...xvi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 30: ...12 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 70: ...52 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 114: ...96 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 123: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix B Notices 105...
Страница 124: ...106 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 129: ......
Страница 130: ...Part Number 43W7037 Printed in USA 1P P N 43W7037...