Solving
undetermined
problems
If
the
diagnostic
tests
did
not
diagnose
the
failure
or
if
the
server
is
inoperative,
use
the
information
in
this
section.
If
you
suspect
that
a
software
problem
is
causing
failures
(continuous
or
intermittent),
see
“Software
problems”
on
page
38.
Damaged
data
in
CMOS
memory
or
damaged
BIOS
code
can
cause
undetermined
problems.
To
reset
the
CMOS
data,
use
the
clear
CMOS
jumper
(J19)
to
clear
the
CMOS
memory;
see
“System-board
jumpers”
on
page
11.
If
you
suspect
that
the
BIOS
code
is
damaged,
see
“Recovering
from
a
BIOS
update
failure”
on
page
46.
Check
the
LEDs
on
the
power
supply.
If
the
LEDs
indicate
that
the
power
supply
is
working
correctly,
complete
the
following
steps:
1.
Turn
off
the
server.
2.
Make
sure
that
the
server
is
cabled
correctly.
3.
Remove
or
disconnect
the
following
devices,
one
at
a
time,
until
you
find
the
failure.
Turn
on
the
server
and
reconfigure
it
each
time.
v
Any
external
devices
v
Surge-suppressor
device
(on
the
server)
v
Modem,
printer,
mouse,
and
non-IBM
devices
v
Each
adapter.
v
Hard
disk
drives.
v
Memory
modules.
The
minimum
configuration
requirement
is
one
512
MB
DIMM.
The
following
minimum
configuration
is
required
for
the
server
to
turn
on:
v
A
microprocessor
v
One
512
MB
DIMM
on
the
system
board
v
A
power
supply
v
Power
cord
v
System
board
4.
Turn
on
the
server.
If
the
problem
remains,
suspect
the
following
components
in
the
following
order:
a.
System
board
b.
Memory
module
c.
Microprocessor
If
the
problem
is
solved
when
you
remove
an
adapter
from
the
server
but
the
problem
recurs
when
you
reinstall
the
same
adapter,
suspect
the
adapter;
if
the
problem
recurs
when
you
replace
the
adapter
with
a
different
one,
suspect
the
system
board.
If
you
suspect
a
networking
problem
and
the
server
passes
all
the
system
tests,
suspect
a
network
cabling
problem
that
is
external
to
the
server.
50
IBM
System
x3105
Type
4347:
Problem
Determination
and
Service
Guide
Содержание x3105 - System - 4347
Страница 1: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 18: ...xvi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 30: ...12 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 70: ...52 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 114: ...96 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 123: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix B Notices 105...
Страница 124: ...106 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 129: ......
Страница 130: ...Part Number 43W7037 Printed in USA 1P P N 43W7037...