2.
The
test
log
data
is
maintained
only
while
the
diagnostic
programs
are
active.
When
you
exit
from
the
diagnostic
programs,
the
test
log
is
cleared.
Save
the
test
log
to
a
file
on
a
diskette
or
to
the
hard
disk
if
you
want
to
refer
to
it
later.
Diagnostic
error
codes
The
following
table
describes
the
error
codes
that
the
diagnostic
programs
might
generate
and
suggested
actions
to
correct
the
detected
problems.
If
the
diagnostic
programs
generate
error
codes
that
are
not
listed
in
the
table,
make
sure
that
the
latest
levels
of
BIOS,
Remote
Supervisor
Adapter
II
SlimLine,
and
ServeRAID
code
are
installed.
In
the
error
codes,
x
can
be
any
numeral
or
letter.
However,
if
the
three-digit
number
in
the
central
position
of
the
code
is
000,
195,
or
197,
do
not
replace
a
CRU
or
FRU.
When
these
numbers
are
in
the
central
position
of
the
code,
they
have
the
following
meanings:
000
The
server
passed
the
test.
Do
not
replace
a
CRU
or
FRU.
195
The
Esc
key
was
pressed
to
end
the
test.
Do
not
replace
a
CRU
or
FRU.
197
This
is
a
warning
error,
but
it
does
not
indicate
a
hardware
failure;
do
not
replace
a
CRU
or
FRU.
Take
the
action
that
is
indicated
in
the
Action
column
but
do
not
replace
a
CRU
or
a
FRU
.
See
the
description
of
Warning
in
“Diagnostic
text
messages”
on
page
41
for
more
information.
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
System
x3105
Type
4347,”
on
page
53
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
001-292-000
Core
system:
failed/CMOS
checksum
failed.
Load
the
BIOS
default
settings
using
the
Configuration/Setup
Utility
program
and
run
the
test
again
(see
“Using
the
Configuration/Setup
Utility
program”
on
page
94).
001-xxx-000
Failed
core
tests.
(Trained
service
technician
only)
Replace
the
system
board.
001-xxx-001
Failed
core
tests.
(Trained
service
technician
only)
Replace
the
system
board.
005-xxx-000
Failed
video
test.
(Trained
service
technician
only)
Replace
the
system
board.
001-197-000
001-198-000
Test
aborted.
1.
Check
the
test
log
for
messages
that
indicate
the
cause
of
the
error,
and
take
the
indicated
action.
2.
Restart
the
server
and
run
the
diagnostic
test
again.
3.
Run
the
Quick
Memory
Test
All
Banks
diagnostic;
then,
if
an
error
is
detected,
take
the
indicated
action.
4.
Reinstall
and,
if
necessary,
update
the
BIOS
code
on
the
server;
then,
run
the
test
again
(see
“Updating
the
firmware”
on
page
93).
42
IBM
System
x3105
Type
4347:
Problem
Determination
and
Service
Guide
Содержание x3105 - System - 4347
Страница 1: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 18: ...xvi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 30: ...12 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 70: ...52 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 114: ...96 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 123: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix B Notices 105...
Страница 124: ...106 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 129: ......
Страница 130: ...Part Number 43W7037 Printed in USA 1P P N 43W7037...