Error
code
Description
Action
201-xxx-PBD
Test
failed:
v
B
=
Failing
bank/pair
number
v
D
=
9
=
Both
DIMMs
in
the
failing
bank/pair
of
DIMMs
v
Reseat
the
failing
DIMMs;
then,
run
the
memory
diagnostics
test
again.
v
Replace
the
failing
DIMMs;
then,
run
the
memory
diagnostic
test
again.
v
(Trained
service
technician
only)
Replace
the
system
board.
204-198-000
Test
aborted.
1.
Run
the
Quick
Memory
Test
Diagnostic
All
Banks
(see
“Running
the
diagnostic
programs”
on
page
40).
2.
Update
the
BIOS
code
(see
“Updating
the
firmware”
on
page
93).
3.
Look
in
the
test
log
(see
“Viewing
the
test
log”
on
page
41)
and
correct
any
other
errors.
204-210-000
Test
failed.
1.
Run
the
Quick
Memory
Test
Diagnostic
All
Banks
(see
“Running
the
diagnostic
programs”
on
page
40).
2.
Update
the
BIOS
code
(see
“Updating
the
firmware”
on
page
93).
3.
Look
in
the
test
log
(see
“Viewing
the
test
log”
on
page
41)
and
correct
any
other
errors.
215-xxx-000
Failed
CD
or
DVD
test.
1.
Run
the
test
again
with
a
different
CD
or
DVD.
2.
Reseat
the
following
components:
a.
CD
or
DVD
drive
cable
b.
Power
switch/LED
bracket
cable
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
CD
or
DVD
drive
cable
b.
CD
or
DVD
drive
c.
Power
switch/LED
bracket
cable
217-xxx-000
Failed
fixed
disk
test.
1.
Reseat
hard
disk
drive
1
cable.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Hard
disk
drive
1
cable
b.
Hard
disk
drive
1
217-xxx-001
Failed
fixed
disk
test.
1.
Reseat
hard
disk
drive
2
cable.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Hard
disk
drive
2
cable
b.
Hard
disk
drive
2
44
IBM
System
x3105
Type
4347:
Problem
Determination
and
Service
Guide
Содержание x3105 - System - 4347
Страница 1: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 8: ...vi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 18: ...xvi IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 30: ...12 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 70: ...52 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 114: ...96 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 123: ...Japanese Voluntary Control Council for Interference VCCI statement Appendix B Notices 105...
Страница 124: ...106 IBM System x3105 Type 4347 Problem Determination and Service Guide...
Страница 129: ......
Страница 130: ...Part Number 43W7037 Printed in USA 1P P N 43W7037...