Chapter 4. Feature installation and configuration
71
Call Home feature
The purpose of the call home feature is to notify the IBM field support staff that a serious
condition may exist at one of their customer sites. A IBM field support person then dials
into the reporting Enterprise Manager using pcAnywhere and determines what
problem(s) exist. Hexidecimal and decimal event codes are used to represent the
triggering events. Currently, call home pages are received for the following events:
Setting up Call Home
Use the following procedure to set up the call home feature.
1. At the Enterprise Manager Client screen, select the Notification Preferences
feature from the File menu. The Notification Preferences screen is displayed.
2. From this screen you can enter the following information:
– Enterprise Manager ID
– Enterprise Manager ID code
– Customer ID
– Customer ID code
– Site ID
– Site contact name
– Site contact phone
– Wait Before Next Notification (in minutes)
– RSM (pcAnywhere) Callback Number
3. After entering all the information, check the system by clicking the Test button.
4. If the test is successful, click the Apply button and then click the OK button.
5. If the test is not successful, recheck the information that was entered.
You can now select and configure the Alphanumeric, Numeric, and E-mail paging
options.
Table 2. Call Home feature event descriptions
Event
Severity
Description
Message
(Hexidecimal)
Message
(Decimal)
FI REPLACE FRU FAN
Error
Individual fan failure
0x6
6
FI REPLACE FRU POWER
SUPPLY
Critical
Power supply failure
0x7
7
FI FAN MAINTENANCE
Critical
Fan assembly failure
0x8
8
FI CABINET OVERHEAT
Critical
Cabinet overheat
0x9
9
FI REPLACE FRU BOARD
Critical
TCM reports TFIO/TSW
board failure
0xBBC
3004
OVER HEAT CONDITION
Error
TCM/TFIO/TSW board
overheat condition
0xBBE
3006
FI RPLACE FRU SFP
Critical
SFP failure
0xFAA
4010
Содержание TotalStorage SAN256N Director 2045-N16
Страница 2: ......
Страница 3: ...IBM TotalStorage SAN256N Director 2045 N16 Installation and Maintenance Guide GC26 7714 00...
Страница 10: ...SAN256N Director 2045 N16 viii...
Страница 12: ...SAN256N Director 2045 N16 x...
Страница 18: ...SAN256N Director 2045 N16 xvi...
Страница 26: ...SAN256N Director 2045 N16 6...
Страница 84: ...SAN256N Director 2045 N16 64...
Страница 94: ...SAN256N Director 2045 N16 74...
Страница 97: ...Chapter 5 Hardware maintenance procedures 77 Figure 33 SAN256N director front chassis FRU locations 1 2...
Страница 120: ...SAN256N Director 2045 N16 100...
Страница 142: ...SAN256N Director 2045 N16 122...
Страница 144: ...SAN256N Director 2045 N16 124...
Страница 156: ......
Страница 157: ...Printed in USA GC26 7714 00...