Appendix A. Data collection and troubleshooting
109
Table 11. TSW problem indications, solution 2
Action
Remove and reseat the board. Verify that the latch
mounting screws are tightened to the proper torque. If the
fault persists, try replacing it with another board. If this
works, it verifies that the board you replaced is faulty. Place
the failed board in an antistatic bag, and return it to IBM.
Heartbeat LED Blink Interval is Not Normal (Normal is On/Off Once per Second)
Problem Summary
There has been a hardware failure.
Probable Cause
The board may not be seated properly, or it may be faulty
Action
Remove and reseat the board. Verify that the latch
mounting screws are tightened to the proper torque. If the
fault persists, try to determine the source of the fault by
interpreting the interval pattern of the Heartbeat LED (see
TCM/TFIO/TSW PROM boot blink codes and TCM/TFIO/
TSW board boot blink codes). Error conditions on the
board are indicated by a three-second delay when the LED
is not lit, followed by a specific distinctive rapid blink interval
rate pattern. Document your findings, and then replace the
board. Place the failed board in an antistatic bag, and
return it to IBM.
Table 10. TSW problem indications, solution 1 (Continued)
PWR OK LED is not lit
Содержание TotalStorage SAN256N Director 2045-N16
Страница 2: ......
Страница 3: ...IBM TotalStorage SAN256N Director 2045 N16 Installation and Maintenance Guide GC26 7714 00...
Страница 10: ...SAN256N Director 2045 N16 viii...
Страница 12: ...SAN256N Director 2045 N16 x...
Страница 18: ...SAN256N Director 2045 N16 xvi...
Страница 26: ...SAN256N Director 2045 N16 6...
Страница 84: ...SAN256N Director 2045 N16 64...
Страница 94: ...SAN256N Director 2045 N16 74...
Страница 97: ...Chapter 5 Hardware maintenance procedures 77 Figure 33 SAN256N director front chassis FRU locations 1 2...
Страница 120: ...SAN256N Director 2045 N16 100...
Страница 142: ...SAN256N Director 2045 N16 122...
Страница 144: ...SAN256N Director 2045 N16 124...
Страница 156: ......
Страница 157: ...Printed in USA GC26 7714 00...