SAN256N Director 2045-N16
60
1. Open the cabinet front panel door.
2. Review the SAN256N director Site Configuration Worksheet and SAN256N director
Fiber Channel Director Port Server/Device Configuration Worksheet to confirm port
assignments and fiber optic cable connections to the ports. These worksheets were
completed during the site planning process.
3. Route the fiber optic cables, that have been designated for ports 0 through 15 on the
top shelf TFIO blades located in chassis slots 0 through 3, through the chassis left
vertical cable trough. The cables are then run up to the top horizontal cable trough
and down to the TFIO ports.
4. Route the fiber optic cables, that have been designated for ports 0 through 15 on the
top shelf TFIO blades located in chassis slots 4 through 7, through the chassis right
vertical cable trough. The cables are then run up to the top horizontal cable trough
and down to the TFIO ports.
5. Route the fiber optic cables, that have been designated for ports 0 through 15 on the
bottom shelf TFIO blades located in chassis slots 0 through 3, through the chassis
left vertical cable trough. The cables are then run up to the middle horizontal cable
trough and down to the TFIO ports.
6. Route the fiber optic cables, that have been designated for ports 0 through 15 on the
bottom shelf TFIO blades located in chassis slots 4 through 7, through the chassis
right vertical cable trough. The cables are then run up to the middle horizontal cable
trough and down to the TFIO ports.
Figure 32. Fiber optic cable assignments
Left Vertical
Cable Trough
Middle Horizontal
Cable Trough
Top Horizontal
Cable Trough
Right Vertical
Cable Trough
Top Shelf
Bottom Shelf
TFIO Blades
TFIO Blades
0
1
2
3
4
5
6
7
TS4 - 0 to 15
TS5 - 0 to 15
TS6 - 0 to 15
TS7 - 0 to 15
BS4 - 0 to 15
BS5 - 0 to 15
BS6 - 0 to 15
BS7 - 0 to 15
TS0 - 0 to 15
TS1 - 0 to 15
TS2 - 0 to 15
TS3 - 0 to 15
BS0 - 0 to 15
BS1 - 0 to 15
BS2 - 0 to 15
BS3 - 0 to 15
TS0 - 0 to 15
Top Shelf Slot #
Port#
BS0 - 0 to 15
Bottom Shelf Slot #
Port#
TFIO Slot Number
Содержание TotalStorage SAN256N Director 2045-N16
Страница 2: ......
Страница 3: ...IBM TotalStorage SAN256N Director 2045 N16 Installation and Maintenance Guide GC26 7714 00...
Страница 10: ...SAN256N Director 2045 N16 viii...
Страница 12: ...SAN256N Director 2045 N16 x...
Страница 18: ...SAN256N Director 2045 N16 xvi...
Страница 26: ...SAN256N Director 2045 N16 6...
Страница 84: ...SAN256N Director 2045 N16 64...
Страница 94: ...SAN256N Director 2045 N16 74...
Страница 97: ...Chapter 5 Hardware maintenance procedures 77 Figure 33 SAN256N director front chassis FRU locations 1 2...
Страница 120: ...SAN256N Director 2045 N16 100...
Страница 142: ...SAN256N Director 2045 N16 122...
Страница 144: ...SAN256N Director 2045 N16 124...
Страница 156: ......
Страница 157: ...Printed in USA GC26 7714 00...