SAN256N Director 2045-N16
118
– For multi- mode TFIO ports (duplex LC connectors), use a multi- mode jumper
cable one meter in length.
4. Power on the power meter and the SAN256N director (if not previously powered on).
Observe that the reading on the power meter is within the minimum and maximum
values, depending upon the type of fiber link, as specified below:
Table 20. Power meter levels
Type of Fiber
Minimum Power Level
Maximum Power Level
Single-mode
-10.0 dBm
3.0 dBm
Multi-mode
-10.0 dBm
4.0 dBm