v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing, Types 7871 and 1949,” on page 41 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
Error code
Description
Action
2018003
One or more option Roms were disabled.
1.
Run the Setup utility (see “Using the Setup
utility” on page 20). Select
Start Options
from
the menu and modify the boot sequence so that
you change the load order of the optional-device
ROM code.
2.
Run the Setup utility (see “Using the Setup
utility” on page 20) and disable unused resource
to make more space available:
v
Select
Start Options
v
Select
Planar Ethernet (PXE/DHCP)
to disable
the on-board Ethernet controller ROM.
v
Select
Advanced Functions
, followed by
PCI
Bus Control
, and then
PCI ROM Control
Execution
to disable the ROM of the adapters
in the PCI slots.
v
Select
Devices and I/O Ports
to disable any of
the on-board devices.
3.
If the problem remains, replace the following
components one at a time in the order shown,
restarting the server each time:
v
Expansion cards (see “Removing an I/O
expansion card” on page 74 and “Installing an
I/O expansion card” on page 78).
v
(Trained service technician only) Replace the
system board (see “Removing the
system-board assembly” on page 94 and
“Installing the system-board assembly” on
page 95).
3018000
TPM communication failure.
(Trained service technician only) Replace the system
board (see “Removing the system-board assembly”
on page 94 and “Installing the system-board
assembly” on page 95).
3018001
Primary FW bank signature invalid.
1.
Run the Setup utility (see “Using the Setup
utility” on page 20), select Load Default Settings,
and save the settings.
2.
(Trained service technician only) Replace the
system board (see “Removing the system-board
assembly” on page 94 and “Installing the
system-board assembly” on page 95)
3018002
Secondary FW bank signature invalid.
1.
Run the Setup utility (see “Using the Setup
utility” on page 20), select Load Default Settings,
and save the settings.
2.
(Trained service technician only) Replace the
system board (see “Removing the system-board
assembly” on page 94 and “Installing the
system-board assembly” on page 95)
Chapter 6. Diagnostics
157
Содержание BladeCenter HS22V 7871
Страница 1: ...BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 20: ...4 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 34: ...18 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 64: ...48 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 112: ...96 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 240: ...224 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 244: ...228 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 252: ...236 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 257: ......
Страница 258: ...Part Number 00Y8038 Printed in USA 1P P N 00Y8038...