v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing, Types 7871 and 1949,” on page 41 to determine which components are CRUs and
which components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error Code
Type
Error Message
Action
0x80070200
Error
Processor
X
, temperature (CPU
X
OverTemp) critical [Note:
X
=1-2]
1.
Make sure that the room temperature is within
the operating specifications (see “Features and
specifications” on page 8).
2.
Make sure that none of the air vents on the
BladeCenter unit and on the blade server are
blocked.
3.
Make sure that all of the fans on the BladeCenter
unit are running.
4.
Make sure that the CPU heat sink is properly
attached to the CPU (see “Installing a
microprocessor and heat sink” on page 88).
0x80070200
Error
System board, voltage (Planar
Fault) critical
1.
Reseat the blade server in the BladeCenter unit
(see “Removing the blade server from the
BladeCenter unit” on page 52 and “Installing the
blade server in a BladeCenter unit” on page 53).
2.
If the error continues, replace the system-board
assembly (see “Removing the system-board
assembly” on page 94 and “Installing the
system-board assembly” on page 95).
0x80070200
Error
Expansion Card 1 (LDC Fault)
critical
1.
Check the operating system event log and the
system event log as it may contain additional
information (see “Error logs” on page 99).
2.
Reseat the blade server in the BladeCenter (see
“Removing the blade server from the BladeCenter
unit” on page 52 and “Installing the blade server
in a BladeCenter unit” on page 53).
3.
Update the device drivers for any expansion cards
that are installed into the blade server.
4.
Reseat the expansion card (see “Removing an I/O
expansion card” on page 74 and “Installing an
I/O expansion card” on page 78).
5.
Replace the expansion card (see “Removing an
I/O expansion card” on page 74 and “Installing
an I/O expansion card” on page 78).
Chapter 6. Diagnostics
107
Содержание BladeCenter HS22V 7871
Страница 1: ...BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 20: ...4 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 34: ...18 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 64: ...48 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 112: ...96 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 240: ...224 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 244: ...228 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 252: ...236 BladeCenter HS22V Type 7871 and 1949 Problem Determination and Service Guide...
Страница 257: ......
Страница 258: ...Part Number 00Y8038 Printed in USA 1P P N 00Y8038...