Control Panel Basic (SIMATIC PANEL)
FAM 25/45/60/75/95
en(us)
Page 69/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
Operating modes - Brief overview / Brief description
The following offers a brief description of the operating modes:
Operating
modes:
Description
DW+FT
= Dewatering
and Filtration
The fluid will be simultaneously dewatered and
filtered.
DWT+
FT
= Dewatering
up to and
Filtration
The fluid will be simultaneously dewatered and
filtered.
The FAM operates until a specified Relative
Humidity has been reached (see page 65).
Afterwards, the FAM switches off. Now the
recurrent inspection interval starts (time until the
unit switches on again, see page 79). After this
has run through, the FAM switches on
automatically once again and runs for at least 2
minutes. If the Relative Humidity is reached once
again after this time, then the FAM will switch off
once again and the recurrent inspection interval
runs again.
DWT + FTB
= Dewater to +
Filter to
The fluid will be simultaneously dewatered and
filtered.
The FAM operates until both specified nominal
values have been reached (see page 65 / 67).
Afterwards, the FAM switches off. Now the
recurrent inspection interval starts (time until the
unit switches on again, see page 79). After this
has run through, the FAM switches on
automatically once again and runs for at least 2
minutes. If the Relative Humidity is reached once
again after this time, then the FAM will switch off
once again and the recurrent inspection interval
runs again.
EW+H+FT
= D
Heat + Filter
The fluid will be simultaneously dewatered and
filtered and heated up to the prescribed
temperature (see page 66).
DWT + H +
FT
= Dewater to +
Heat + Filter
The fluid will be simultaneously dewatered and
filtered and heated up to the prescribed
temperature (see page 66).
The FAM operates until a specified Relative
Humidity has been reached (see page 65).
Afterwards, the FAM switches off. Now the
recurrent inspection interval starts (time until the
unit switches on again, see page 79). After this
has run through, the FAM switches on
automatically once again and runs for at least 2
minutes. If the Relative Humidity is reached once
again after this time, then the FAM will switch off
once again and the recurrent inspection interval
runs again.
DWT + H +
FTB
= Dewater to +
Heat + Filter
to
The fluid will be simultaneously dewatered and
filtered and heated up to the prescribed
temperature (see page 66).