Control Panel Basic (SIMATIC PANEL)
FAM 25/45/60/75/95
en(us)
Page 65/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
RH+P (Relative Hu Pressure)
Start screen -> MENU1 -> RF-D
F1
F2
F3
F4
START =
Start
FAM
Display in operating status "Ready for operation" and with the
error message "Water content
≥
90%, measurement with CS
not possible".
STOP =
Stop
FAM.
is displayed only in the operating status "Starting phase" and
"Automatic operation"
RESET
= Reset error messages
Is displayed only in the presence of faults
MENU1
= Switch to MENU1
Display :
Rel. humidity: tgt:
= The nominal value can be changed from 0 - 99%.
Factory setting: 30%
Rel.humidity: act:
= Display of the current moisture at the FAM inlet.
A display of 0 - 100% is possible.
Temp.
= Medium temperature at inlet to the FAM.
Pressure
= Current pressure (absolute) in the vacuum column
The displayed temperature is measured at the inlet by the AquaSensor.
START
MENU1
RH
+P
Rel. moisture: Nominal:
30
%
Actual:33%
Temp 22°C Pressure: 970 mbar(abs )
Ready for operation. Please press Start
STOP
RESET