Error messages / troubleshooting
FAM 25/45/60/75/95
en(us)
Page 143/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
30. Malfunction CS flow too low.
Cause:
The charge pump for the CS runs for 2 minutes in automatic
mode. The CS reports "Flow too low" or "Device error" for 4
minutes, message appears in the display of the CS. The FAM
continues to run. The CS is switched off for 15 seconds.
If the operating mode "Filter to" is set and the fault appears
3x in a row, then the message will also appear in the windows
"Start screen, RH+P, T and CS".
No additional limitations.
Remedy:
Select a different operating mode, normal mode is possible.
31. Fault, CS device error
Cause:
The charge pump for the CS runs for 2 minutes in automatic
mode. The CS reports "Flow too low" or "Device error" for 4
minutes, message appears in the display of the CS. The FAM
continues to run. The CS is switched off for 15 seconds.
If the operating mode "Filter to" is set and the fault appears
3x in a row, then the message will also appear in the windows
"Start screen, RH+P, T and CS".
No additional limitations.
Remedy:
Select a different operating mode, normal mode is possible.