Starting up the FAM
FAM 25/45/60/75/95
en(us)
Page 53/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
Switching on the FAM
Move main switch to the "ON" position and wait until the "Fault" lamp lights up briefly
(lamp test) and the following start screen will appear after 30 seconds.
The most recently selected operating mode will be shown in the display.
Select an operating mode with heater in the presence of viscosities
≥
350 mm²/s.
It is not mandatory that the heater be switched on in the presence of
lower viscosities, but it would contribute decisively to the enhancement
of dewatering performance.
Select the operating mode (OM) as described on page 68.
F1
F2
F3
F4
F1 = start FAM
F4 = switch to MENU1
Press the START key. The FAM begins with the starting phase.
The power unit control switches to the RF+D menu.
The vacuum pump starts up, the filling pump conveys and the vacuum
column is filled.
Set the required negative pressure in the vacuum column. See page 54.
The evacuation pump is switched on and the starting period is finished when
the vacuum chamber is filled to the MAX filling level.
The FAM controller switches over to automatic operation.
Bleed the filter housing as described on page 56.
Operating mode: Dewa Filtration
START
MENU1
Ready for operation, please press Start