Error messages / troubleshooting
FAM 25/45/60/75/95
en(us)
Page 135/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
25. Oil tank of rotary vane vacuum pump is too full -> drain oil
Cause:
The MAX switch point in the oil tank of the rotary vane
vacuum pump has been reached for 10 minutes. The
message appears on the display. The FAM goes into the
after-running phase and switches off.
Remedy:
Perform the following steps:
Step
Description
1. Message:
25. Oil tank of rotary vane vacuum pump is too full -> drain oil
2.
Empty the oil tank of the rotary vane vacuum pump until the level in the
inspection glass is between MIN and MAX. To drain, use the drain ball
valve on the vacuum pump.
3.
Actuate ESC key and reset failure with the F3 key.
4.
Start the unit by pressing the F1 key.
5.
The fault is repaired.
If the failure recurs, even though there is enough vacuum pump oil in
the rotary vane vacuum pump, first check the float switch and
afterwards the PLC.